Function introduction
This product is used for chemical and chemical high-pressure synthesis or catalytic reactions where the temperature, speed and inert gas addition, pressure levelling and online sampling are required.
Technical highlights.
1.The whole reaction process can be observed during the reaction.
2.The observation window is made of JGS2 high transmittance quartz glass for on-line photochemical reactions under high pressure.
Application examples: for photochemical high pressure reactions, CO2 reduction, CO2 reduction to methanol
CO2 reduction to methane CH4, reduction and degradation of NOx, high-pressure photocatalytic degradation of formaldehyde, etc.
decomposition of formaldehyde, etc. Photocatalytic reactions, Fischer-Tropsch reactions, hydrogenation reactions, polymerisation reactions, homogeneous reactions and supercritical reactions with CO2, etc.
Volume |
10ml |
Material |
UL316L |
Working pressure |
≤12.5MPa |
Valve and connectionmaterial |
SU316L |
Reactor chamber |
fully encapsulated in PTFE |
Temperature Range |
0-300ºC |
Evaporatingrange |
0-1200 rmp |
Safe pressure |
12.5Mpa |
Pipe outer diameter |
3mm |
wall thickness |
1mm |
Stirring power |
100W |
Toom temperature |
280 °C |
Temperature control accuracy |
<±0.5 °C |
The kettle cover is distributed as two gas channels and one liquid sampling, one for safe pressure relief, one for pressure display, and one for temperature measurement in the kettle. |
The whole device is equipped with a set of special hydrogenation and inflation hoses for high-pressure hydrogen cylinders. |
Precautions.
1: To ensure safe use please make sure to connect the earth wire, please do not work with empty material or dry burning.
2: In order to prolong the use of the product, the motor of the magnetic stirrer is equipped with a fan cooling function, so when doing heating experiments, especially high temperature heating experiments, the instrument can not be used for heating alone, do not set the motor to rotating or medium speed rotating state (or idle). To prevent damage to the motor and electrical appliances by high temperature radiation.
3: When the high-temperature heating is finished, please turn off the heating switch first, and then turn off the stirring switch after the residual temperature has dissipated for a few minutes. The heating part is hot, so be careful when working to avoid burns.
4:When the new machine is used for the first time, there is white smoke and odour coming out of the set heated by electric heating wire, the colour changes from white to brown and then to white.
5: When the liquid benefits into the set, please quickly turn off the power supply, the instrument will be placed in a ventilated place to dry before use, in order to avoid leakage or electrical short circuit danger.
6: If the humidity is too high, inductive electricity may be transmitted to the housing through the insulation layer, please make sure to connect the earth wire to avoid leakage and pay attention to ventilation. Relative humidity range 35%-85% (non-condensing)
7: When not in use for a long time, please store the instrument in a dry and non-corrosive environment.
8: If the product or the products covered by this manual are modified and the contents of this manual are different without notice, please call the manufacturer for details.
Package Detail
1) Wooden packing
2) The goods can be shipped by sea, air or train, small goods or spare parts will be shipped by express.
3) You can choose your own freight forwardwe as well.
4) Door to Door Delivery to save your energy and time. We'll take the all risks during transportation.
Shipping Details
1) AMERICA:3-8 working days.
2) ASIAN:3-8 working days.
3) EUROPE:5-10 working days.
4) OCEANIA:4-9 working days.
5) AFRICA:7-13woring day.
Xi'an Taikang Biotechnology Co., Ltd, is a famous manufacturer of Lab equipment located in the central China. Now has TAIKANG, TKA two well-known brand trademarks. The main products include ultra-high temperature and high pressure reactor, high pressure photochemical reactor, supercritical high pressure reactor, high pressure glass reactor, micro high pressure reactor, high pressure ultrasonic reactor, Ultra-high temperature hydrothermal synthesis reactor, photocatalytic reactor, visual catalytic reactor, hydrothermal synthesis reactor, rotary evaporator, parallel synthesis reactor, high and low temperature circulator, high and low temperature high pressure tubular reactor and other equipment and so on.
Specialize in this field for more than 20 years,TKA brand instrument has own high reputation in more than 70 countries and regions, provide technical support for tens of thousands organizations to solve problems within their research, special for university, research institutes, industries, inspection agencies, etc. Promoting technology progress and improving human life is TKA social mission.
Q1:Are you trading company or manufacturer?
A1:We are professional manufacture of lab equipment and we have our own factory which is a high-tech enterprise integrating R&D, production and sales. And welcome to visit our factory.
Q2: How long is your delivery time?
A2: Usually, delivery time is 30-45 days after receiving your payment.
Q3:How to shipping the replacement parts?
A3:We will according the actual situation to choose the suitable shipping ways. For small parts we shippin by Express.
Q4: How about your quality warranty ?
A4: Normally all TKA products are supplied with a warranty of 12 Months from the date of shipment.
Q5: Do you accept OEM and ODM orders?
A5: Yes,We accept.
Q6:What is your terms of payment?
A6:Payment≤15,000USD, 100% in advance. Payment≥15,000USD, 70% T/T in advance, balance before shipment.
(If you are concerned about payment security for the first order, we advise you can place Trade Assurance Order via Made in China. you will get 100% payment refund if we can't meet agreed delivery time.)
Q7:Can we visit your factory?
A7: Welcome visit our factory.