When this product is used for chemical, chemical high-pressure synthesis or catalytic reaction, it is necessary to measure the temperature, measure the rotational speed, add inert gas, stabilize the pressure and realize the required experimental environment such as online sampling.
Technical Advantage:
- The entire reaction process can be observed during the reaction.
- The observation window adopts JGS2 high transmittance quartz glass to realize online photochemical reaction under high pressure.
Application example:
Suitable for photochemical high pressure reaction, carbon dioxide CO2 reduction, carbon dioxide CO2 reduction to methanol
Reduction of carbon dioxide CO2 to methane CH4, reduction and degradation of nitrogen oxides NOx, high-pressure photocatalytic degradation of formaldehyde
solution, etc. Photocatalytic reaction, Fischer-Tropsch reaction, hydrogenation reaction, polymerization reaction, homogeneous reaction and carbon dioxide supercritical reaction, etc.
Model Specification
PN |
Size |
Volume |
Connecion Model |
Pore diameter |
|
Display Accuracy |
WGHX-25ML |
Φ40*60 |
25ml |
Screw Thread |
30mm |
Yes |
±1ºC |
WGHX-50ML |
Φ60*80 |
50ml |
Flange |
40mm |
Yes |
±1ºC |
WGHX-100L |
Φ80*120 |
100ml |
Flange |
40mm |
Yes |
±1ºC |
WGHX-200ML |
Φ80*140 |
200ml |
Flange |
60mm |
Yes |
±1ºC |
WGHX-500ML |
Φ100*240 |
500ml |
Flange |
60mm |
Yes |
±1ºC |
Volume |
25ml,50ml,100ml,200ml,500ml,Can be costomized |
Reactor Material |
Stainless steel 316L/Titanium/Hastelloy (optional) |
Operating pressure |
10MPa/20MPA(optional) |
Valve and Connecting material |
Stainless steel SU316L |
Reactor liner container: |
inner sleeve easy to clean |
Transparent window material: |
using polished JGS2 quartz glass (pressure window) or sapphire mirror |
Operating temperature |
The Max tem.p is 350ºC for Titanium/Hastelloy (optional),The Max tem.p is 250ºC for stainless steel.The tem.p display accuracy is ±1ºC. |
Max pressure/Min Pressure |
10Mpa/1Pa |
mixing speed |
0-1500RPM |
Speed Accuracy |
±5RPM |
Power Supply |
220V,50HZ, |
The valve fittings are of European standard, and the interfaces are all standard configuration. The ball valve can be connected with the bottle filled with inert gas to carry out the inert protection experiment reaction, so that the reactant is not in direct contact with the air. |
Package Detail
1) Wooden packing
2) The goods can be shipped by sea, air or train, small goods or spare parts will be shipped by express.
3) You can choose your own freight forwardwe as well.
4) Door to Door Delivery to save your energy and time. We'll take the all risks during transportation.
Shipping Details
1) AMERICA:3-8 working days.
2) ASIAN:3-8 working days.
3) EUROPE:5-10 working days.
4) OCEANIA:4-9 working days.
5) AFRICA:7-13woring day.
Xi'an Taikang Biotechnology Co., Ltd, is a famous manufacturer of Lab equipment located in the central China. Now has TAIKANG, TKA two well-known brand trademarks. The main products include ultra-high temperature and high pressure reactor, high pressure photochemical reactor, supercritical high pressure reactor, high pressure glass reactor, micro high pressure reactor, high pressure ultrasonic reactor, Ultra-high temperature hydrothermal synthesis reactor, photocatalytic reactor, visual catalytic reactor, hydrothermal synthesis reactor, rotary evaporator, parallel synthesis reactor, high and low temperature circulator, high and low temperature high pressure tubular reactor and other equipment and so on.
Specialize in this field for more than 20 years,TKA brand instrument has own high reputation in more than 70 countries and regions, provide technical support for tens of thousands organizations to solve problems within their research, special for university, research institutes, industries, inspection agencies, etc. Promoting technology progress and improving human life is TKA social mission.
We welcome new and old customers from all over the world to contact us for future business relationships and achieving mutual success!!
Q1:Are you trading company or manufacturer?
A1:We are professional manufacture of lab equipment and we have our own factory which is a high-tech enterprise integrating R&D, production and sales. And welcome to visit our factory.
Q2: How long is your delivery time?
A2: Usually, delivery time is 30-45 days after receiving your payment.
Q3:How to shipping the replacement parts?
A3:We will according the actual situation to choose the suitable shipping ways. For small parts we shippin by Express.
Q4: How about your quality warranty ?
A4: Normally all TKA products are supplied with a warranty of 12 Months from the date of shipment.
Q5: Do you accept OEM and ODM orders?
A5: Yes,We accept.
Q6:What is your terms of payment?
A6:Payment≤15,000USD, 100% in advance. Payment≥15,000USD, 70% T/T in advance, balance before shipment.
(If you are concerned about payment security for the first order, we advise you can place Trade Assurance Order via Made in China. you will get 100% payment refund if we can't meet agreed delivery time.)
Q7:Can we visit your factory?
A7: Welcome visit our factory.